[Free] 2018(Jan) EnsurePass Testking CompTIA ISS-001 Dumps with VCE and PDF 21-30

Ensurepass.com : Ensure you pass the IT Exams
2018 Jan CompTIA Official New Released ISS-001
100% Free Download! 100% Pass Guaranteed!
http://www.EnsurePass.com/ISS-001.html

Intel? Server Specialist Certification Exam

Question No: 21

Which of the following utilities can an Intel? Server Specialist use to configure the BMC remote access settings? (Select THREE).

  1. syscfg.efi

  2. FRUSDR

  3. fwpiaupd.efi

  4. BIOS setup utility

  5. IDA

  6. OFU

Answer: A,D,E

Question No: 22

A customer calls and explains that after a server had been working for six months, it now seems to have developed a fault. The status LED is amber coloured and the fans are spinning at full speed. The technician does not have remote access to the system. Which of the following utilities would be the BEST to run in order to diagnose the issue?

  1. sysinfo

  2. IDA

  3. OFU

  4. selview

Answer: A

Question No: 23

Which of the following is a direct benefit of the Intel? AES-NI technology in the Intel? Xeon? 5600 Series Processors?

  1. Provides a secure interface for virtual machines

  2. Allows for automatic energy savings

  3. Increased encryption and decryption performance

  4. Provides an autonomous Ethernet interface

Answer: C

Question No: 24

A customer has a system based on an Intel? Workstation Board S5520SC, with 2 Intel? Xeon? Processors X5670 and 12x DDR3 ECC RDIMMs populated. The system is reporting memory failures on DIMM A1. The company’s Specialist swaps this DIMM with a known working one, and the error remains on DIMM slot A1. Next the Specialist replaces the processor and motherboard, and the error still persists on the same slot. Which of the following is the MOST likely cause of this error?

  1. There is an issue with the operating system.

  2. The power supply is supplying an incorrect voltage on the 1.5V line.

  3. There is a motherboard standoff installed in the wrong position.

  4. The chassis has not been earthed properly.

Answer: C

Question No: 25

An Intel? Server Specialist has just integrated a system and has now powered it on for the first time. The monitor stays black and the specialist hears three beeps. Which of the following is the MOST likely cause of this?

  1. BMC self test failure

  2. BIOS corruption

  3. Faulty processor

  4. Incompatible memory

Answer: D

Question No: 26

An Intel? Server Specialist has an Intel? Server Board S5520HC based system with a RAID 1 volume on the onboard SATA RAID controller, and Windows Server 2003 SP2 installed. Which of the following does the specialist need in order to enable email alerting in

case of a RAID failure?

  1. An Intel? Remote Management Module 3

  2. EFI Raid Command Tool

  3. RAID Web Console 2

  4. BMC configured for alerting using the Intel? Deployment Assistant CD

Answer: C

Question No: 27

Intel provides firmware update packages for the Intel? Modular Server. Can an Intel? Server Specialist simply use these to update a system, whenever a new package becomes available?

  1. No, the installation instructions must be checked for minimum firmware levels before the update.

  2. Yes, update, provided this is the first time you are integrating the system following initial build.

  3. Yes, the system will automatically update itself from any previous firmware level to the current level.

  4. No, you should never upgrade the firmware on the Intel? Modular Server

Answer: A

Question No: 28

Which of the following items are required, to allow the use of SATA SSD drives, in an Intel? Modular Server Chassis MFSYS25? (Select THREE).

  1. The latest drive firmware from the hard drive manufacturer

  2. Firmware level 4.0 or higher

  3. Do not mix drive types (SAS/SATA) within a storage pool

  4. Firmware level 5.0 or higher

  5. AXXTM3 SATA converter

Answer: C,D,E

Question No: 29

Where does the Intel? Modular Server store the CMM amp; Ethernet switch configuration information?

  1. On a small section of the hard drives installed in the system.

  2. On the SD card that plugs into the chassis mid-plane.

  3. On the flash EEPROM in the Chassis Management Module.

  4. In the flash EEPROM of each individual component.

Answer: B

Question No: 30

Where does the Intel? Modular Server store its storage configuration information?

  1. On a small section of the hard drives installed in the system.

  2. In the flash EEPROM of each individual component.

  3. On the SD card that plugs into the chassis mid-plane.

  4. On the flash EEPROM in the Chassis Management Modules.

Answer: A

100% Ensurepass Free Download!
Download Free Demo:ISS-001 Demo PDF
100% Ensurepass Free Guaranteed!
ISS-001 Dumps

EnsurePass ExamCollection Testking
Lowest Price Guarantee Yes No No
Up-to-Dated Yes No No
Real Questions Yes No No
Explanation Yes No No
PDF VCE Yes No No
Free VCE Simulator Yes No No
Instant Download Yes No No

Leave a Reply